Assessment of External Gamma Dose Rates and Radiological Contamination in Iraqi Water Sources
Main Article Content
Abstract
An extensive radiological analysis was performed on 50 samples in total, 25 samples of common tap water and 25 commercial mineral water samples, which were selected in the different local markets and cities in Iraq, to be analyzed properly and in standard polypropylene beakers. To examine the possible variation of behavior of radionuclides to determine whether or not there was any change, three main parameters, that is, the Surface Contamination (Bq/cm2), the Dose rate (µSv/h), and the General Count Rate (Cps) were measured using a portable RadEye B20 survey detector in two states namely the as-collected state and the controlled boiling state. The researchers concluded that mineral water displayed slightly lower mean radiological parameters than tap water where mean values pre-boiling included Tap Water 0.295 (Bq/cm2), 0.205 (µSv/h), and 0.509 (Cps) whereas means before boiling was Mineral Water 0.275 (Bq/cm2), 0.185 (µSv/h), and 0.469 (Cps). The statistically insignificant effect on subsequent detector readings was the effect the boiling process had which was within the internal error/sensitivity range of the instrument. Finally, all the water samples produced very low radiological results thus coming to the concluding that both tap and mineral water usage in the analyzed areas of Iraq represent non-significant radiological concern to the human health condition since all the radiological parameters of all samples were much lower than the recommended international intervention norms.